Product Description:
The FRDCS series power isolated DC power supply with high control precision, quick response, perfect protection function and two-way operation.
Applications:
Test and aging of Fuel cell DC/DC converter;
Test and aging of motor & controller;
Charge and discharge test of various power batteries;
Product Models and Technical Parameters:
Product models |
Rating |
Accuracy of setting |
Ripple |
AC input |
|||||||||||||
Voltage |
Current |
Power |
Voltage |
Current |
Voltage |
Current |
Voltage |
Frequency |
Max current |
||||||||
FRDCS-150KT |
20~800V |
800A |
150kW |
≤0.1%FS |
<0.1%FS+5dgt |
≤1.6Vp-p |
≤1Arms |
380Vac±10%, 3P+PE |
50Hz±5% |
240A |
|||||||
FRDCS-200KT |
20~800V |
800A |
200kW |
320A |
|||||||||||||
FRDCS-250KT |
24~800V |
800A |
250kW |
400A |
|||||||||||||
Product models |
Overload operation |
Number of units in parallel |
Distortion rate of total input current |
Power factor |
DC component |
||||||||||||
FRDCS-150KT |
110%for long time running |
Max 4 units in parallel and max output current reaches 3200A |
<3%@rated power |
>0.99 |
<5%@rated power |
||||||||||||
FRDCS-200KT |
|||||||||||||||||
FRDCS-250KT |
|||||||||||||||||
Product models |
General |
||||||||||||||||
Dimensions |
Weight |
Isolation method |
Protection level |
Operating temperature |
Highest altitude |
||||||||||||
FRDCS-150KT |
W1202*D897*H1903 mm |
1500kg |
built-in isolation transformer |
IP21 |
-30~55℃ |
6000m(no derating below 3000m) |
|||||||||||
FRDCS-200KT |
1600kg |
||||||||||||||||
FRDCS-250KT |
1700kg |
||||||||||||||||
Product models |
General |
||||||||||||||||
Communication method |
Display |
Cooling method |
Noise |
Relative humidity |
|||||||||||||
FRDCS-150KT |
CAN/RS485 |
Color touch screen |
AF(intelligent temperature control air cooling) |
<70dB@1m |
0~95%,no condensation |
||||||||||||
FRDCS-200KT |
|||||||||||||||||
FRDCS-250KT |
Note: All the specification may change and can be customized, please refer to Foripower for the latest information.