EN
CNEN

DC Electronic Load

DC Electronic Load

The FRDCS series isolated DC load with high control precision, fast response, perfect protection function and two-way operation.

product details

Product introduction

The FRDCS series isolated DC load with high control precision, fast response, perfect protection function and two-way operation.

Technical advantages

Bi-directional flow of DC load, which adapts to energy feedback and dynamic response of test system;

Can operate with 1.1 times overload for long time;

Wide DC voltage range;

Built-in power frequency isolation transformer;

High control precision, fast response and perfect protection function;

The man-machine interface adopts LCD touch screen design, which is convenient and quick to operate

Max 8 units in parallel and max output current reaches 6400A.

Applications

Test and aging of Fuel cell and DC/DC converter;

Test and aging of power supply products;

Charge and discharge test of various power batteries;

Test and aging of E&E equipments.

Product parameters

Model

FRDCS-50KT

FRDCS-120KT

FRDCS-250KT

FRDCL-100KT

FRDCL-150KT

FRDCL-250KT

Rating

voltage

60~500V

200~850V

480~850V

20V~800V

20V~800V

50V~800V

current

500A

600A

520A

800A

800A

800A

power

50kW

120kW

250kW

100kW

150kW

250kW

Response time

< 10 ms

Operating mode

Constant voltage, constant current, constant resistance, and constant power

Overload operation

110% for long time running

Number of units in parallel

Max 8 units in parallel and max output current reaches 4000A

Max 8 units in parallel and max output current reaches 6400A

Accuracy of setting

voltage

0.1%FS+5dgt

0.1%FS+5dgt

current

0.5%FS

0.1%FS

AC input

voltage

380Vac±10%, three-phase three-wire

frequency

50Hz±5%

max current

80A

190A

397A

160A

238A

397A

Distortion rate of  total input current

 

3%@rated power

Power factor

 

0.99

DC component

 

5%@rated power

General parameters

dimension

1000x1800x850

1200x1800x850

weight

1300kg

1300kg

1400kg

1500kg

1700kg

2000kg

isolation method

built-in isolation transformer

protection level

IP21

IP21

operating temperature

-30~55

highest altitude

6000mno derating below 3000m

communication method

CAN/RS485

display

Color touch screen

cooling method

AFTemperature controlled forced air cooling

noise

75dB@1m

65dB@1m

relative humidity

0~95%no condensation

Protective function

over-voltage & under-voltage protection

over-current protection

over-temperature protection

About Foripower
Corporate Introduction
Milestones
Foripower News
PowerProducts
Fuel Cell DC/DC Converter
Vehicle-mounted DC/DC Converter
Compressor Motor Controller
Power Control Unit
Testing&Manufacture
DC Source
DC Electronic Load
Power Generation Inverter
R&D
R&D Center
Work Shop
Contact Us
Contact Us
Map
  1. +86 137 2868 6158 (dugy@foripower.com)
  2. +86 189 2602 6142
  3. Scan
    Focus on us