Product Model |
FRDCL-120KTS |
FRDCL-150KTS |
FRDCL-200KTS |
FRDCL-250KTS |
FRDCL-350KTS |
|
DC input parameters |
|||||
|
Voltage range |
20~800VDC |
30~800VDC |
50~800VDC |
50~800VDC |
50~800VDC |
|
Maximum current |
800A |
||||
|
Rated power |
120kW |
150kW |
200kW |
250kW |
3 50kW |
|
Current accuracy |
<0.1%FS+5dgt |
||||
|
Current response |
<20ms (10%FS→90%FS) |
||||
|
voltage accuracy |
<0.1%FS (constant voltage mode) |
||||
|
Voltage response |
<20ms (10%FS→90%FS) (Constant voltage mode) |
||||
|
AC output parameters |
|||||
|
Voltage range |
380VAC±10% |
||||
|
Number of phases |
Three-phase three-wire 3P+PE |
||||
|
Frequency range |
50Hz±5% |
||||
|
Maximum current |
175A |
220A |
320A |
400 A |
56 0 A |
|
Power factor |
≥0.99@rated power |
||||
|
Current harmonics |
<3%@rated power |
||||
|
DC component |
<0.5%@rated power |
||||
|
Isolation methods |
Power frequency transformer isolation |
||||
|
System parameters |
|||||
|
System efficiency |
>95% max. >92% @ rated power |
||||
|
Parallel operation |
Supports 8 units operating in parallel |
||||
|
Communication methods |
CAN / RS485 |
||||
|
Local interface |
Color Touchscreen |
||||
|
Operating mode |
Constant voltage mode (CV), constant current mode (CC), constant resistance mode (CR), constant power mode (CP) |
||||
|
Other parameters |
|||||
|
External dimensions |
W1200 * D850 * H1900 mm |
||||
|
weight |
1500kg |
1600kg |
1800kg |
1,900 kg |
1,950 kg |
|
Protection level |
IP21 |
||||
|
Operating temperature |
-30~55℃ |
||||
|
Working altitude |
6,000 m (derated above 3,000 m) |
||||
|
Cooling method |
AF (Intelligent Temperature Control Air Cooling) |
||||
|
noise |
<70dB@1m Rated power |
||||
|
relative humidity |
0~95%, no condensation |
||||
|
Protection parameters |
|||||
|
DC reverse polarity protection |
It is capable of operating without DC reverse connection and will upload fault information. |
||||
|
Phase sequence error |
It is capable of not operating when there is a phase error and will upload fault information. |
||||
|
Over/under voltage protection |
It features DC over/under voltage protection and AC over/under voltage protection. |
||||
|
Overcurrent protection |
It features power module overcurrent protection, AC overcurrent protection, and DC overcurrent protection. |
||||
|
Over- temperature protection |
It features inductor over-temperature protection, power module over-temperature protection, and environmental over-temperature protection. |
||||
|
Residual current protection |
It features power-off protection when leakage current exceeds 30mA to ensure personal safety. |
||||