Product Series |
FRA24C |
FRA24T |
|
DC input parameters |
||
|
Voltage range |
400~ 850VDC |
|
|
AC output parameters |
||
|
Rated current |
65~120 Arms |
120 ~ 150 Arms |
|
Maximum current |
130 Arms (1.2s) |
1 7 0 Arms (1.2s) |
|
Rated power |
30~ 60 kW |
60 ~ 75 kW |
|
Maximum frequency |
3kHz/ 180,000rpm ( one-pole permanent magnet synchronous motor ) |
|
|
Total Harmonic Content (THDi) of Current |
< 5 % @ Rated current (minimum value, related to motor parameters) |
|
|
Low-order harmonic current content |
≤3% (5th, 7th, 11th, 13th) @ Rated current (minimum value, related to motor parameters) |
|
|
System parameters |
||
|
Peak efficiency |
>98% |
|
|
Initialization time |
<1s (0→idle speed) |
|
|
Downtime |
<1s (idle speed → 0, related to the allowable value of energy feedback) |
|
|
Response time |
<100ms (Command issued → Speed change) |
|
|
Communication methods |
CAN 2.0B 250kbps or 500kbps |
|
|
Auxiliary power supply |
9~36VDC |
|
|
Motor temperature sampling |
Standard PT1000 / PT100 |
|
|
Other parameters |
||
|
External dimensions |
L315*W272*H92 |
L380.4*W273*H117.8mm |
|
Weight |
8kg |
11kg |
|
Protection level |
IP67 |
IP54 |
|
Operating ambient temperature |
-40~85℃ |
|
|
Storage ambient temperature |
-40~105℃ |
|
|
Water pipe diameter |
φ1 6 mm |
φ14mm |
|
Coolant temperature |
-40~65℃ |
|
|
Rated flow rate |
8 L/min |
12L/min |
|
Insulation withstand voltage |
>100MΩ . 3500VDC |
|
|
Protection parameters |
||
|
Motor protection function |
Over-temperature (self-recoverable), overcurrent, overspeed, phase current imbalance |
|
|
DC input protection |
Over/under voltage protection (self-recoverable) |
|
|
Auxiliary power supply protection |
Over/under voltage protection (self-recoverable) |
|
|
Power module protection |
Over-temperature protection (self-recoverable), direct-flow protection |
|
|
Other protections |
Environmental over-temperature protection (self-recovering) |
|